Learn
When A1c can mislead
A1c depends on red blood cells and hemoglobin. Anything that changes them can push the result up or down.
Changes in red blood cell lifespan
Conditions that change how long red blood cells live can change A1c. NIDDK lists recent blood loss, sickle cell disease, erythropoietin treatment, hemodialysis and transfusion (NIDDK). The ADA's list adds hemolysis, splenectomy and G6PD deficiency (ADA Standards 2026, sec. 2).
After blood loss, a transfusion or giving birth
A1c reflects glucose attached to hemoglobin over the life of red blood cells, about 120 days (ADA Standards 2026, sec. 2). When many red blood cells are lost or replaced, the result no longer matches recent glucose well. The ADA names recent blood loss and recent blood transfusion among the conditions that can interfere with A1c accuracy (ADA Standards 2026, sec. 2) (ADA Standards 2026, sec. 6). Neither the ADA nor NIDDK gives a fixed waiting time before an A1c is reliable again.
Childbirth is one case the ADA spells out. For people who had gestational diabetes, it recommends a glucose tolerance test rather than A1c at 4 to 12 weeks after delivery, because A1c may stay lowered by blood loss at delivery and by the faster red blood cell turnover of pregnancy (ADA Standards 2026, sec. 15).
Low iron
A falsely high A1c can occur in people who are very low in iron, for example with iron-deficiency anemia (NIDDK). More in A1c and anemia. For results that read low, see low A1c.
Kidney and liver disease
Kidney failure and liver disease are other causes of false A1c results (NIDDK).
Hemoglobin variants
People of African, Mediterranean or Southeast Asian descent, or with family members who have sickle cell anemia or thalassemia, may carry a hemoglobin variant that interferes with some A1c tests. Most carriers have no symptoms and do not know. Not all A1c tests are affected; a different test method can be used (NIDDK). The NGSP keeps information on which methods suit which variants (NGSP).
Pregnancy
A1c may be used early in pregnancy to look for diabetes that was present before. Gestational diabetes is usually checked with glucose tests between 24 and 28 weeks (NIDDK). More in A1c in pregnancy.
Signs something is off
Doctors may suspect interference when A1c and glucose results do not match (NIDDK). See A1c high, glucose normal for every reason the two can disagree. If you use a CGM, a large gap between your GMI and your lab A1c is worth raising too (Bergenstal 2018).
What is used instead
In conditions that change how A1c relates to glucose, including those that alter red blood cell turnover, the ADA says plasma glucose tests should be used to diagnose diabetes (ADA Standards 2026, sec. 2). For monitoring diabetes, the alternatives include glucose meter checks, CGM, and fructosamine or glycated albumin, which reflect the past 2 to 4 weeks rather than months (ADA Standards 2026, sec. 6).
Normal test variation
Even on the same sample, repeat tests vary a little. NIDDK gives the example that a 6.8% result could read anywhere from 6.4% to 7.2% on a repeat test (NIDDK). A retest that comes only a few weeks after a change can also look stuck; see how fast A1c can change. Home kits have a wider margin than labs; see home A1c tests.
Frequently asked questions
How long after a blood transfusion is A1c accurate?
The ADA and NIDDK say a recent transfusion can make A1c inaccurate, but they do not give a set waiting time. A1c is built up over the life of red blood cells, about 120 days, so a transfusion or major blood loss mixes in cells that have not been exposed to your own glucose for that long. Your care team decides when a new A1c makes sense or uses glucose tests meanwhile.
Does giving blood affect A1c?
The guidelines list recent blood loss as something that can change A1c; they do not mention blood donation separately. If you gave blood shortly before an A1c test, tell the person ordering it.
Why is A1c not used right after giving birth?
The ADA recommends a glucose tolerance test rather than A1c at 4 to 12 weeks after delivery for people who had gestational diabetes, because A1c may be lowered by blood loss at delivery and by the faster red blood cell turnover of pregnancy.
What is used instead when A1c is unreliable?
For diagnosis, the ADA says plasma glucose tests should be used. For monitoring diabetes, it lists glucose meter checks, CGM, and fructosamine or glycated albumin, which reflect the past 2 to 4 weeks.
Sources
- National Institute of Diabetes and Digestive and Kidney Diseases (NIH). The A1C Test & Diabetes. www.niddk.nih.gov/health-information/diagnostic-tests/a1c-test
- American Diabetes Association Professional Practice Committee. 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes 2026. Diabetes Care. 2026;49(Suppl 1). doi.org/10.2337/dc26-S002
- American Diabetes Association Professional Practice Committee. 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes 2026. Diabetes Care. 2026;49(Suppl 1). doi.org/10.2337/dc26-S006
- American Diabetes Association Professional Practice Committee. 15. Management of Diabetes in Pregnancy: Standards of Care in Diabetes 2026. Diabetes Care. 2026;49(Suppl 1):S321-S338. doi.org/10.2337/dc26-S015
- NGSP. IFCC Standardization of HbA1c: the IFCC and NGSP master equation (NGSP = 0.09148 x IFCC + 2.152). ngsp.org/ifccngsp.asp
- Bergenstal RM, Beck RW, Close KL, et al. Glucose Management Indicator (GMI): a new term for estimating A1C from continuous glucose monitoring. Diabetes Care. 2018;41(11):2275-2280. doi.org/10.2337/dc18-1581
Written and maintained by the controla1clevels.com editorial team. We do not have a medical reviewer; every claim links to its primary source above. Last reviewed: 2026-10-28. Spotted an error? See About.